A lift that misses its annual test, or a building that ignores a structural inspection notice, rarely points to a bad technician. More often, nobody owned the calendar. Facilities manager outsourcing in Singapore works best when you hand one person that calendar on day one and explain what each date means.
This guide covers the recurring inspections a facilities manager has to track, what the Building and Construction Authority (BCA) says about each one, and what to check before you bring someone in.
Table of Contents
ToggleWhat a facilities manager owns
ProSkill Workforce describes the facilities manager role as covering everything from maintenance and security to workspace optimization, with attention to compliance rules and sustainable practices. That is a broad brief, and it is easy to hire against the wrong half of it. Some sites need a manager who runs contractors and budgets. Others need one who keeps the statutory paperwork current.
Decide which half matters most, then write it down. Our guide to facilities management staffing covers the team around the role. This post covers the compliance side, because that is where a missed date costs the most.
Lifts and escalators: monthly maintenance, annual testing
BCA sets maintenance schedules for lifts and escalators, and a BCA-registered service contractor does the work. For most lifts, maintenance runs at the manufacturer’s frequency or at least once every month, whichever is more frequent. If the Commissioner of Building Control approves remote monitoring and diagnostics in writing, the approved schedule applies instead. Escalators are maintained every month.
Every lift and escalator also needs an annual inspection and test. The service contractor carries it out with an independent Specialist Professional Engineer present. Owners must also apply to BCA for a permit to operate before a lift or escalator goes into use. The application needs a completed form, an AE certificate confirming the unit is fit for operation, and the fee.
| Equipment | Maintenance schedule (BCA) | Annual inspection and test |
|---|---|---|
| Other lifts | Manufacturer’s frequency or at least once every month, whichever is more frequent; the Commissioner’s approved schedule applies where remote monitoring and diagnostics is approved in writing | Yes, with an independent Specialist Professional Engineer present |
| Stairlifts and vertical platform lifts (not serving a single residential unit) | Manufacturer’s schedule or every 3 months, whichever is more frequent | Yes |
| All escalators | Every month | Yes |
Ask every candidate how they track these dates and whom they chase when the contractor slips. Our post on handyman and facilities maintenance covers the everyday repairs that sit around the lift schedule.

Periodic structural inspection
BCA requires a periodic structural inspection (PSI) for non-residential buildings once every 5 years and for residential buildings once every 10 years. Detached, semi-detached and terraced houses are excluded. So are linked houses used only for residence, and temporary buildings. A Structural Engineer carries out the inspection.
Responsibility sits with the building owner. For strata-titled developments, the management corporation (MCST) takes it on. After a PSI Notice arrives, the owner must appoint a Structural Engineer within the stipulated timeframe and give site access. The owner also makes sure the engineer submits the report to BCA on time and carries out any rectification within the deadline. BCA’s page does not state those timeframes in months, so read the notice itself and diarise every date it gives.
Periodic facade inspection
Buildings over 20 years old must be inspected every seven years under BCA’s periodic facade inspection (PFI) regime, with specific exceptions. The owner appoints a Competent Person, who may bring in a Facade Inspector working under direct supervision. Drone-based visual inspections need an accredited UAS service provider, and the Competent Person must notify the Commissioner of Building Control through BCA’s e-Form.
The owner has to repair any defects the Competent Person finds. If an exterior feature falls, call BCA’s Safety Incident Hotline within 6 hours of becoming aware and submit the incident report within 24 hours. A facilities manager who is not ready for that scenario is a gap worth closing. Our guide to facade inspection plans that work goes deeper.
Build one calendar for every recurring duty
Put each duty in one place, with a named owner and a backup. The table below pulls together the BCA items covered in this post.
| Duty | Interval or trigger | Who does the work |
|---|---|---|
| Lift and escalator maintenance | Monthly for escalators and most lifts | BCA-registered service contractor |
| Annual inspection and test of lifts and escalators | Once a year | Service contractor, with an independent Specialist Professional Engineer present |
| Periodic structural inspection | Every 5 years (non-residential) or 10 years (residential), after a PSI Notice | Structural Engineer appointed by the owner |
| Periodic facade inspection | Every 7 years for buildings over 20 years old, with exceptions | Competent Person appointed by the owner |
| Fallen exterior feature | Hotline call within 6 hours, report within 24 hours | Owner, through BCA’s channels |
Fire certificates run on their own cycle. Our guides to the three-year fire certificate and fire certificate requirements explain that side, and the fire safety manager checklist covers the day-to-day duties.
Facilities manager outsourcing or a permanent hire?
A permanent facilities manager suits a building where the role becomes the institutional memory. Outsourcing fits a handover period, cover for a resignation, or a site where you want to test the scope before committing. Agree a minimum placement period at the start, because a manager who rotates every few months resets the calendar each time.
Our posts on when companies should outsource hiring and outsourcing versus recruitment set out the trade-offs in more detail.

What to ask a facilities manager candidate
Interview questions that expose real experience:
- Which statutory inspections have you tracked, and how did you diarise them?
- Can you show a compliance calendar you built, with names removed?
- What did you do when a contractor missed a maintenance visit?
- Have you handled a PSI or PFI notice from receipt to report?
- How would you brief a duty officer on the hotline steps for a fallen exterior feature?
- Which systems or software will you need access to on day one?
How ProSkill Workforce supplies facilities managers
ProSkill Workforce lists facilities managers among its engineering and facilities professionals for commercial and industrial sites. Tell us the building type, age and equipment, and we will match the person to the compliance load, not just the title.
For hands-on cover around the manager, see our pages on facilities maintenance technicians, plumbing for facilities that cannot pause and safe and compliant electrical works. Buildings that need a fire safety manager can use a part-time option, covered in our post on supplying part-time fire safety managers.
Facilities manager outsourcing: frequently asked questions
What does a facilities manager do in Singapore?
The scope changes from site to site. ProSkill describes the role as covering maintenance, security and workspace optimization, with attention to compliance and sustainable practices. Write down which half of that brief matters most before you hire.
How often do lifts need maintenance?
BCA says most lifts need maintenance at the manufacturer’s frequency or at least once every month, whichever is more frequent. Escalators need maintenance every month. Every lift and escalator also needs an annual inspection and test.
How often is a periodic structural inspection required?
Once every 5 years for non-residential buildings and once every 10 years for residential buildings, according to BCA. A Structural Engineer carries it out after the owner receives a PSI Notice.
Which buildings need a periodic facade inspection?
BCA says buildings over 20 years old must be inspected every seven years, with specific exceptions. The owner appoints a Competent Person and repairs any defects found.
Who is responsible for these inspections?
The building owner is responsible for both PSI and PFI. For strata-titled developments, the MCST takes on the PSI responsibility.
When does facilities manager outsourcing make sense?
It suits handovers, cover for a resignation, and sites where you want to test the scope first. Agree a minimum placement period so the person does not rotate out before the calendar is under control.
Need a facilities manager for your building?
For facilities manager outsourcing that starts with your compliance calendar, send us the building type, its age, the lifts and equipment on site, and the start date. Call +65-90900468 or +65-88338400, or email inquiry@proskillworkforce.com. You can also use our contact page. We’ll reply with candidates matched to the load you describe. ProSkill Global Recruitment Pte Ltd, EA Licence No. 26C3677 (Comprehensive Licence), provides recruitment and placement; see our recruitment services page.